
If you are responsible for building safety, you need a simple way to confirm that your fire doors remain in good working order. A clear fire door inspection checklist helps you record what was checked, identify defects and track the action required.
The good news is that you can create a practical checklist in around five minutes.
This guide provides a plain-English template that you can copy, adapt and use across your buildings. It is suitable for building owners, landlords, property managers, facilities managers and other duty holders managing fire door compliance.
Important: The 3-monthly and annual statutory fire door checks described below apply to qualifying multi-occupied residential buildings in England where the top storey is above 11 metres. Your fire risk assessment and wider fire safety arrangements may require additional inspections or maintenance.
What is a fire door inspection checklist for?
A fire door inspection checklist gives you a consistent method for reviewing each door. It helps you check the visible condition of the door and frame, confirm that the door closes correctly and record any work needed.
A good checklist should help you answer five simple questions:
- Which building and door were checked?
- When was the inspection completed?
- What condition was the door in?
- What defects or concerns were identified?
- What action is required, and has it been completed?
Using the same format each time makes your records easier to review. It also helps you demonstrate a clear approach to fire safety management and supports the information needed for your fire risk assessment.
Your checklist should not replace a suitable fire risk assessment or a detailed inspection by a competent professional where serious damage, uncertain door performance or complex repairs are identified.
Understanding statutory fire door checks
For qualifying multi-occupied residential buildings in England, statutory fire door checks include:
- Checks of fire doors in communal areas at least every three months.
- Annual checks of flat entrance fire doors, using best endeavours.
- Checks of self-closing devices.
- Records of the checks completed and reasonable steps taken to gain access where required.
The 3-monthly communal check and the annual flat entrance check are routine visual checks. They are not necessarily the same as a comprehensive fire door inspection or a programmed maintenance visit.
The government’s fire door guidance explains the scope of these checks in more detail. You can also read our previous guide, 7 Mistakes You’re Making with Statutory Fire Door Checks, for a fuller explanation of the difference between routine checks, inspections and maintenance.
Step 1: Add the basic door information
Start your fire door inspection checklist with a short information section.
Record:
- Building name and address
- Floor or level
- Door ID or asset number
- Exact door location
- Door type, such as communal, flat entrance, stairwell or plant room
- Date and time of inspection
- Name of person completing the check
- Inspection type, such as 3-monthly check or annual flat entrance check
Giving every door a unique ID makes future inspections much easier. You can compare the current result with previous findings and confirm that no doors have been missed.
Step 2: Use a simple outcome system
Keep the result easy to understand. For each checklist item, use:
- Pass – no visible issue identified
- Fail – a defect or concern requires action
- N/A – the item does not apply to that door
Add a comments or actions box beside each item. This gives the person completing the check enough space to explain what they found without creating unnecessary paperwork.

Step 3: Copy this fire door inspection checklist
Use the following checklist for each fire door. Adapt it to suit your building, fire risk assessment and inspection arrangements.
1. Door leaf condition
Check the main door leaf for visible damage or defects.
- Is the door leaf free from cracks, holes, splitting, warping or impact damage?
- Is the surface in reasonable condition, with no damage that could affect fire or smoke resistance?
- Does the door sit correctly within the frame?
- Has the door been cut, planed, drilled or otherwise altered?
- Is the door free from signs of unauthorised repair or replacement?
Record any damage clearly. Take a photograph where the defect may be difficult to explain in words.
2. Frame and gaps
Inspect the frame and the space around the closed door.
- Is the frame secure and free from splitting, distortion or significant damage?
- Is the frame firmly fixed to the surrounding wall?
- Are the gaps around the door reasonably even?
- Is there any excessive gap between the door leaf and frame?
- Is the bottom gap as small as reasonably practicable without causing the door to drag?
Government guidance states that the gap between the door and frame should not be too large. As a general guide, gaps should not exceed approximately 4mm except at the bottom, although the correct assessment depends on the door and its condition.
3. Intumescent and brush seals
Look around the door edges and frame for intumescent strips and smoke seals, where fitted.
- Are the seals present where expected?
- Are they continuous and securely fitted?
- Are they damaged, split, loose or missing?
- Have they been painted over or blocked by debris?
- Do brush seals make suitable contact when the door is closed?
Do not assume that every existing door must have the same type of seal. If you are uncertain about the original specification or suitability of the door, arrange a more detailed review rather than making an unsupported change.
4. Hinges and fixings
Check the hinges and visible fixings carefully.
- Are all hinges present and securely attached?
- Are there any missing, loose or damaged screws?
- Is there any visible movement, corrosion or distortion?
- Are fixings secure in both the door leaf and frame?
- Does the door move smoothly without catching?
Loose hinges can affect the way a door closes and may contribute to excessive gaps. Any repair or replacement should use suitable components and be completed by a competent person.
5. Self-closing device operation
The self-closing device is a key part of your fire door inspection.
- Is the self-closing device present where required?
- Is it securely fixed?
- Is there any visible damage, leakage or disconnection?
- Does the door close fully into the frame when released?
- Does it close from a fully open position?
- Does it close from approximately 15 degrees?
- Does it overcome the resistance of the latch and any floor friction?
The door should close fully without assistance. If it stops short, catches or requires force to shut, record this as a defect and arrange suitable action.

6. Latches and locks
Check that the door hardware supports reliable closure.
- Does the latch engage correctly when the door closes?
- Is the lock or latch damaged, loose or sticking?
- Are all visible fixings present?
- Does the hardware prevent the door from closing fully?
- Have any locks, viewers or other items been removed, leaving holes or damage?
Do not force a door to close or adjust hardware without considering the door’s specification. Unsuitable replacement parts or uncontrolled alterations can affect fire door compliance.
7. Glazing and vision panels
If the door contains glazing or a vision panel, inspect it carefully.
- Is the glass intact, with no cracks or missing sections?
- Are glazing beads secure?
- Are the surrounding seals in good condition?
- Is there any evidence that the glazing has been replaced or altered?
- Is the vision panel free from damage that could affect the door’s performance?
If the type or fire performance of the glazing is uncertain, refer the matter for further assessment.
8. Signage
Check that the correct signage is present and legible.
- Is the “Fire door keep shut” sign present where required?
- Is the sign securely fixed?
- Is it clear and easy to read?
- Is any additional “Fire door keep locked” or similar signage appropriate for the door’s use?
Signage should communicate the correct instruction without being damaged, obscured or removed.
9. Hold-open devices
Some communal doors may use approved electromagnetic hold-open or swing-free devices.
- Is the hold-open device securely fitted?
- Is the door released correctly when the fire alarm or local release is activated?
- Does the door close fully after release?
- Is the device being used as designed?
- Is the door being held open by a wedge, hook, bin or other unauthorised object?
A fire door should not be wedged or propped open. Where an approved hold-open device is fitted, follow the building’s procedure for testing it safely. Do not interfere with fire alarm equipment unless you are authorised and competent to do so.
10. Damage or alterations
Finish by checking for any other issue that could affect the door.
- Is there impact damage, vandalism or corrosion?
- Has the door been decorated in a way that affects seals or hardware?
- Are there unauthorised holes, cut-outs, vents or fittings?
- Has the door been replaced or substantially altered?
- Is there any issue not covered by the checklist that should be investigated?
When in doubt, record the concern and seek professional advice. A clear record is more useful than an uncertain pass.
Step 4: Record findings and actions
A checklist is only effective when findings lead to appropriate action.
For every failed item, record:
- Door ID and location
- Date identified
- Description of the defect
- Photographs
- Recommended action
- Priority or target completion date
- Person responsible
- Date repaired
- Follow-up inspection result
Keep a record of access attempts for annual flat entrance checks where access is not available. This may include letters, emails, appointment offers and follow-up visits.
Review the checklist after every inspection cycle. Your review should confirm that all doors were visited, defects were allocated, repairs were completed and outstanding items were carried forward.
For frequently used communal doors, you may also benefit from informal monitoring between scheduled checks, particularly where doors are exposed to heavy traffic, deliveries or repeated impact.
Managing your checklist more efficiently
A paper checklist can work for a small site, but larger portfolios quickly create multiple forms, spreadsheets, photographs and repair records.
FD Check’s custom-built digital inspection app brings these details together. Developed by fire door inspectors, the system streamlines inspections, reduces manual paperwork and creates a complete digital database of fire doors across your premises.
That means you can track each door, review its inspection history, attach photographs, identify outstanding defects and manage repairs more efficiently.

Professional support for fire door compliance
At FD Check, we provide comprehensive fire door inspection and maintenance services for building owners, landlords, property managers, facilities managers and other duty holders.
Our qualified inspectors carry out annual and 3-monthly statutory checks, helping you maintain a consistent inspection programme across your buildings. When defects are identified, our programmed repair service helps you plan and complete the required work. We also provide emergency callouts where a damaged or defective fire door requires prompt attention.
Our efficient processes and digital inspection technology help reduce costs without compromising on quality or safety. With more than 10 years of experience, over 500,000 completed inspections and more than 500 satisfied clients, we understand how to provide reliable fire door compliance support at scale.
Don’t compromise on fire safety or record keeping. Contact FD Check today to discuss your fire door inspection, fire door maintenance and statutory checking requirements. We are happy to help you create a clearer, more cost-effective approach to managing your premises.
